Description

RTC Control Register 2 (in Calendar Count Mode)

Fields

START

Start

0 (0): Stop prescaler and time counter

1 (1): Operate prescaler and time counter normally

RESET

RTC Software Reset

0 (0): In writing: Invalid (writing 0 has no effect). In reading: Normal time operation in progress, or an RTC software reset has completed.

1 (1): In writing: Initialize the prescaler and target registers for RTC software reset. In reading: RTC software reset in progress.

ADJ30

30-Second Adjustment

0 (0): In writing: Invalid (writing 0 has no effect). In reading: Normal time operation in progress, or 30-second adjustment has completed.

1 (1): In writing: Execute 30-second adjustment. In reading: 30-second adjustment in progress.

RTCOE

RTCOUT Output Enable

0 (0): Disable RTCOUT output

1 (1): Enable RTCOUT output

AADJE

Automatic Adjustment Enable

0 (0): Disable automatic adjustment

1 (1): Enable automatic adjustment

AADJP

Automatic Adjustment Period Select

0 (0): The RADJ.ADJ[5:0] setting from the count value of the prescaler every minute.

1 (1): The RADJ.ADJ[5:0] setting value is adjusted from the coun tvalue of the prescaler every 10 seconds.

HR24

Hours Mode

0 (0): Operate RTC in 12-hour mode

1 (1): Operate RTC in 24-hour mode

CNTMD

Count Mode Select

0 (0): Calendar count mode

1 (1): Binary count mode

Links

() ()